The Easiest to use and Most Accurate Near-Field Probes on the Market Today
ScanEM Model CTM020 probes are the most versatile, affordable, and handy instruments for detecting, locating and measuring of electromagnetic emission. Professionals in small and large companies all over the world use ScanEM probes.
ScanEM-C Probe Kit Model CTK015 (includes E- and H-Field Probes with RF and DC output), batteries, 6' RF cable, heavy-duty plastic storage enclosure and User's Guide
ScanEM Probe Kit CTK010 (includes E- and H-Field Probes with no output), batteries, heavy-duty plastic storage enclosure and User's Guide
Model CTA211 RF Signal Accessories for EM Eye® and EM EYE®-DL
E-Field Probe - flat response from 2 MHz to 2.4 GHz, Usable up to 5 GHz
ScanEM®-QC
E & H-Field Probes For Production and QA
ScanEM-QC probes were originally designed for, and in cooperation with, the FCC in order to enable their inspectors to check for violators of rules in the field. After their successful test and adoption of the probes for FCC use, now these probes are available for engineers, technicians and QA inspectors to test their products the same way the FCC does.
ScanEM-QC Probe Kit Model CTK019 (includes radiated and conducted probes with RF and DC output), batteries, 6' RF cable, heavy-duty plastic storage enclosure and User's Guide
EMC Kit
Electromagnetic Compliance Training Kit E & H-Field Probes
EMC Training KitModel CTK031 an EMC Course in a box. Learn the ins and outs of EMC diagnostics.
Includes:
Same probes as ScanEM-C above
EMI Demo Fixture CTA201
BNC/Banana Plug adapter
BNC/N adapter
6' (1.8m) SMC/BNC Cable
Spare 9V Battery
Training guide
User's Guide
Storage Case
Shielding
Picture
Model
Description / Features
CTC112
Radiated Emission CTC116
Conducted Emission
Active Remote Broadband Sensors
Monitoring of the Signals from Transmitters and on Data Cables with Model CTC112 and Model CTC116
Active remote broadband sensors models CTC112 (radiated emission - E-field) and CTC116 (conducted emission) allow for measurement and monitoring of electromagnetic fields in remote locations. Each sensor has built-in low-noise preamplifier with ~15dB of gain and drives standard 50 Ohms input of any test equipment, such as spectrum analyzer, oscilloscope, etc.
EMAlert®
EMI Monitor
EMAlert® Model CTC022 and Model CTC026 modules installed inside of critical equipment continuously monitor emission level, as well as its amplitude modulation since the latter can cause more damage that steady field. Until the level of EMI exceeds preset level (user-set), EMAlert® modules are just passive observers. The moment the interference exceeds the preset level, however, EMAlert® module sends signal that the EM EventTM has occurred and then begins to probe the host equipment by sending pulses every 3ms. The host equipment is supposed to respond with similar pulses if it continues to function properly. Should the host fail to respond,EMAlert® issues Equipment Failure signal and, if desired, attempts to reset the host.